Setbacks, height, and floor area: the building envelope explained
A lot zoned for six homes can be practically limited to four once its building envelope is drawn. Setbacks pull the building in from the property lines, a height limit caps how tall it climbs, and a floor-area ratio caps how much total home fits regardless of footprint or height. All three apply at once, and the design that survives every one of them is what actually gets permitted.
Part of Which multiplex fits your lot, and what shape it can take. Figures re-verified 2026-09-20.
Key takeaways
- Vancouver's R1-1 zone sets a base floor space ratio of 0.70, rising to 1.0 when a project is secured rental or includes a below-market ownership unit.
- Height caps differ by city: about 11.5 m in Vancouver's R1-1, three storeys and 10 m for a front building in Burnaby, and two and a half storeys and 10 m in Richmond's RSM zones.
- Burnaby's R1 small-scale district controls bulk through setbacks and site coverage rather than a floor-area ratio, so its envelope carries no separate FSR backstop.
- The BC Building Code requires at least 45 minutes of fire-resistance rating in the separation between adjoining multiplex units, which takes real space out of each home's usable interior.
Three controls that apply at the same time
Setbacks set the minimum distance the building keeps from the front, rear, and side property lines. What remains after subtracting them is the buildable footprint. Height caps how tall the building climbs above grade. Floor area, expressed as a floor space ratio, caps the total interior square footage regardless of footprint or height. A design has to satisfy all three simultaneously, and loosening one rarely frees up room under the others.
This is why a lot's theoretical unit count, based on area and frontage alone, is often higher than what the envelope actually delivers. If setbacks leave a narrow footprint, adding a storey can recover floor area, but only up to the height cap. Once that ceiling is reached, the floor-area ratio still has to be satisfied within whatever footprint and height remain.
How the envelope differs across Vancouver, Burnaby, and Richmond
Vancouver's R1-1 zone sets a base floor space ratio of 0.70, which can rise to 1.0 when the project is registered as secured rental or includes a below-market ownership unit, a meaningful swing on the same lot depending on how it is built. Height under R1-1 runs up to roughly 11.5 metres for multiplex forms.
Burnaby's R1 small-scale district does not use a floor-area ratio at all. Bulk is controlled through setbacks and site coverage instead, with a front principal building held to three storeys and 10 metres and rear buildings lower still. Because there is no FSR backstop, reading the setbacks and coverage correctly carries more weight on a Burnaby lot than it does in Vancouver.
Richmond's RSM zones cap height at two and a half storeys and 10 metres and limit site coverage to 45 percent of the lot, a real constraint on footprint for the low-lying, flood-sensitive lots common in the city.
| City | Height cap | Floor area control |
|---|---|---|
| Vancouver (R1-1) | About 11.5 m | FSR 0.70 base, up to 1.00 with rental or below-market terms |
| Burnaby (R1) | 3 storeys / 10 m, front building | No FSR; controlled by setbacks and site coverage |
| Richmond (RSM) | 2.5 storeys / 10 m | 45% site coverage cap, no single FSR figure cited here |
The 2026 FSR exclusion for near-zero-emission buildings
Vancouver's zoning bylaw excludes up to 19 percent of floor area from the FSR calculation for buildings that meet near-zero-emission standards equivalent to BC Energy Step Code 5. In practical terms, a project designed to that performance level can add floor area that does not count against the base 0.70 or bonused 1.00 ratio, which is a direct design lever for an owner weighing a high-performance build against a standard one.
This exclusion sits alongside, not instead of, the rental and below-market routes to a higher FSR. A project can pursue the Step Code 5 exclusion on its own, or in combination with a secured rental registration, and the two are evaluated separately against the bylaw.
Party walls take real space out of the envelope
The BC Building Code requires a fire separation with a fire-resistance rating of not less than 45 minutes between adjoining multiplex units. Those assemblies have real thickness and usually carry the acoustic separation that keeps one home from hearing its neighbour. The usable interior of each unit ends up smaller than the raw floor-area number suggests, once wall thickness, stairs, and per-unit mechanical space are accounted for.
A floor plan drawn against the raw FSR number without allowing for this loses real livable space once construction documents are finalized. Building the allowance in from the first design pass avoids that late correction.
Frequently asked questions
What is a building envelope in multiplex design?
A building envelope is the three-dimensional space a zoning bylaw allows construction within, set by the setbacks on each property line, the height limit above, and the floor-area cap. Every multiplex in Vancouver, Burnaby, or Richmond has to fit inside its own envelope, and the envelope, not the unit count alone, decides what a lot can actually support.
What is floor space ratio and how does it work?
Floor space ratio, or FSR, expresses the total permitted floor area as a multiple of lot area. An FSR of 1.0 on a 4,000 square foot lot permits roughly 4,000 square feet of total floor area. It caps the total amount of interior space independently of the building's footprint or height, so a design can satisfy every setback and stay under the height limit and still be stopped by the FSR cap.
What is Vancouver's FSR for a multiplex under R1-1?
Vancouver's R1-1 zone sets a base floor space ratio of 0.70, which can rise to 1.00 when the project is registered as 100 percent secured rental tenure or includes a below-market ownership unit. The same lot can carry meaningfully more total floor area depending on which of those terms the project is built to.
How tall can a multiplex be in Vancouver, Burnaby, or Richmond?
The caps differ by city. Vancouver's R1-1 zone allows multiplex forms up to about 11.5 metres. Burnaby holds a front principal building to three storeys and 10 metres, with rear buildings lower. Richmond's RSM zones cap height at two and a half storeys and 10 metres. Because height is measured from grade, and grade can slope across a lot, how it is measured matters as much as the number itself.
Does Burnaby use a floor area ratio for multiplexes?
No, not in the way Vancouver does. Burnaby's R1 small-scale district controls building bulk mainly through setbacks, site coverage, and height rather than a single floor-area-ratio figure. That makes reading the setbacks and coverage correctly especially important on a Burnaby lot, since there is no separate FSR number acting as a backstop.
What does the near-zero-emission FSR exclusion mean for a multiplex?
Vancouver's zoning bylaw excludes up to 19 percent of floor area from the FSR calculation for buildings meeting near-zero-emission standards equivalent to BC Energy Step Code 5. A project built to that performance level can add usable floor area that does not count against the base 0.70 or bonused 1.00 ratio, which is a real design lever for an owner comparing a high-performance build against a standard one.
Can I get a variance if my design does not fit the envelope?
Sometimes, through a variance or relaxation, but these are case-by-case decisions and never guaranteed regardless of how reasonable the request seems. It is safer to design a multiplex that fits the standard envelope than to make a project's viability depend on an approval that may not be granted.
Why is site coverage different from floor area ratio?
Site coverage limits the percentage of the lot the building footprint can occupy, protecting yard space and permeable ground for drainage, while floor area ratio limits total interior square footage regardless of footprint. Richmond's RSM zones cap site coverage at 45 percent, a real constraint on a low-lying, flood-sensitive lot even before height or floor area come into play.
Does the floor area calculation include the walls between units?
The building code requirement sits alongside the floor area calculation rather than inside it. The BC Building Code requires at least 45 minutes of fire-resistance rating in the separation between adjoining multiplex units, and those assemblies take up real thickness. The usable interior of each unit ends up smaller than the raw floor-area number implies once that allowance is built in.
Go deeper in the Journal
Sources and references
Rate and regulation figures on this page were re-verified on 2026-09-20. Construction cost ranges come from Venture Pacific's own Metro Vancouver projects and are described as such wherever they appear.
- Zoning and Development By-law, R1-1 District ScheduleCity of Vancouver. Accessed 20 September 2026.
- Multiplexes / R1-1Shape Your City Vancouver. Accessed 20 September 2026.
- BC Building Code, Section 9.10 Fire ProtectionGovernment of British Columbia. Accessed 20 September 2026.