Township of Langley zoning bylaw, section 1060
Zone CD-160: Comprehensive Development Zone CD-160
A housing zone for one development of at most 32 homes, with buildings up to 3 storeys, or 2 storeys for homes that face 206 Street.
Site named in the bylaw: Homes facing 206 Street (named in Section 1060.5)
1 lots and 1 strata properties carry this zone in the Township of Langley lot records.
How many homes
- The zone allows at most 32 homes for the whole development. This is a total for all the lands in the zone, so no count for one lot is given here. (section 1060.2)
The rules of zone CD-160
What the zone allows
- Buildings and uses that serve a main use on the same lot (accessory buildings and uses). (section 1060.1 1))
- Home businesses, following Section 104.3. (section 1060.1 2))
- Homes, following Section 1060.2: at most 32 homes, only where the drawing named in Section 1060.11 shows them. Section 1060.2 calls them dwelling units and gives no building type. (section 1060.1 3) and 1060.2)
Lot size for new lots
- New lots made by subdivision must follow Section 110 of this bylaw and the Subdivision and Development Servicing Bylaw 2019 No. 5382. (section 1060.6)
- New lots made by subdivision must be at least 0.65 ha (1.61 acres). (section 110.1)
How much of the lot buildings may cover
- How much of the lot buildings may cover is set in the development permit, a permit from the Township that sets the design of the project. (section 1060.3)
Height
- Main buildings may be at most 3 storeys high. Homes that face 206 Street may be at most 2 storeys. (section 1060.5)
- Accessory buildings may be at most 3.75 m (12 ft 4 in) high and 1 storey, whichever is lower. (section 1060.5)
- Inside the Fort Langley area shown on the map in Section 104.5 3), buildings may be at most 9 m (29 ft 6 in) high and at most 2 storeys, with no room above the second storey. (section 104.5 2))
Distance from the property lines
- The distances buildings must keep from property lines are set in the development permit, a permit from the Township that sets the design of the project. (section 1060.4)
- A heat pump or air conditioner may not be placed on a wall facing a side property line, or inside the required side distance, unless that side faces a side street or lane. It must be at least 1.5 m (4 ft 11 in) from every property line. (section 104.4 12))
Parking
- Parking and loading spaces must follow Section 107 of the bylaw. (section 1060.8)
- In a residential comprehensive development zone, up to 20% of the required visitor spaces may be small car spaces, if each one is set at a right angle to the aisle, is at least 2.44 m (8 ft) by 4.88 m (16 ft), and has a sign saying it is for small cars only. (section 107.5 7))
- Lots in the Willowbrook Transit-Oriented Area need no parking spaces for homes, except spaces for people with disabilities. Any spaces built there for homes must have electric car charging outlets. (section 107.1 3))
- When the parking count comes out with a part of 0.5 or more, it is rounded up to the next whole space. (section 107.2 4))
Other rules
- Landscaping, screens and fences must follow Section 111 of the bylaw and the development permit. (section 1060.7)
- A development with more than 4 townhouse, apartment or seniors' housing homes needs age-friendly amenity areas (shared indoor or outdoor space for the residents' cultural, social and recreation activities): at least 6 m² (65 sq ft) for each of the first 186 homes and 4 m² (43 sq ft) for each home after that. Each area must be at least 70 m² (753 sq ft), and at most half of the required area may be indoors. The development permit also sets them. (section 1060.9, 111.5 1), 2) a) and 6), and 102)
- Council must issue a development permit (a permit that sets the design of the project) before a building permit is issued. (section 1060.10)
- Development must closely follow Drawing A1.1 by Aplin & Martin, dated April 16, 2021. The bylaw names this drawing but does not print it. (section 1060.11)
- In a residential comprehensive development zone, all home businesses on a lot may use at most 25 m² (269 sq ft) of floor space in total. Everyone who runs the home business must live in that home, and the business may only be an office run mainly by phone, computer or other communication equipment. (section 104.3 f) v), g) iv) and l))
Source: Township of Langley Zoning Bylaw No. 2500, Section 900 Comprehensive Development Zones. Section numbers are the bylaw's own.
Questions about zone CD-160
What is zone CD-160 in the Township of Langley?
CD-160 is the Comprehensive Development Zone CD-160 in the Township of Langley zoning bylaw (section 1060). A housing zone for one development of at most 32 homes, with buildings up to 3 storeys, or 2 storeys for homes that face 206 Street.
How many homes can I build in zone CD-160?
The zone allows at most 32 homes for the whole development. This is a total for all the lands in the zone, so no count for one lot is given here.
How tall can I build in zone CD-160?
Main buildings may be at most 3 storeys high. Homes that face 206 Street may be at most 2 storeys. Accessory buildings may be at most 3.75 m (12 ft 4 in) high and 1 storey, whichever is lower.
How many lots are zoned CD-160?
The Township of Langley lot records list 1 lots and 1 strata properties in zone CD-160, on 1 streets.
Streets with lots in zone CD-160
Contains information licensed under the Township of Langley's Open Government License.
