Willoughby, Township of Langley
Lot PID 032-864-931: zoning and what you can build
Lot PID 032-864-931 is a 3,201 m² (34,457 sq ft) lot in Willoughby, Township of Langley. It is zoned CD-196 (Comprehensive development). The number of homes is set by floor area: the floor space ratio of the land zoned CD-196 may be at most 1.56 (all floor area divided by lot area). The bylaw gives no count for one lot. Sources: Township of Langley Zoning Bylaw No. 2500, Section 900 Comprehensive Development Zones, section 1096, and Township of Langley lot records downloaded October 28, 2026.
Homes allowed
No fixed number for one lot
The number of homes is set by floor area: the floor space ratio of the land zoned CD-196 may be at most 1.56 (all floor area divided by lot area). The bylaw gives no count for one lot.
Zone
CD-196
Comprehensive Development Zone CD-196
Lot size
3,201 m² (34,457 sq ft)
Measured from the lot outline in the public map data.
Home count: Township of Langley Zoning Bylaw No. 2500, Section 900 Comprehensive Development Zones, section 1096.2.
What the public records say about this lot
- Municipality
- Township of Langley
- Community plan area
- Willoughby
- Neighbourhood
- Jericho
- Lot size (measured from the lot outline)
- 3,201 m² (34,457 sq ft)
- Lot size the Township records (not verified)
- .785 acres
- Parcel ID (PID)
- 032-864-931
- Legal description
- LT 1, SEC 22, TWP 8, NWD, PL EPP146985
- Plan number
- EPP146985
- Sewer service (Township records)
- None recorded
- Water service (Township records)
- None recorded
- Urban containment boundary (Metro Vancouver)
- Inside
Zone CD-196
What zone CD-196 allows
An apartment zone at a floor space ratio of up to 1.56, with shops, child care and places of worship or culture allowed on the ground floor and buildings up to 6 storeys.
- Apartments (section 1096.1 3))
What the zone allows
- Buildings and uses that serve a main use on the same lot (accessory buildings and uses). (section 1096.1 1))
- Home businesses, following Section 104.3. (section 1096.1 2))
- Apartments: buildings with at least 3 homes, each the permanent home of one family. Each apartment may have one lock-off unit. (section 1096.1 3) and 102)
- Commercial uses: shops, services and repairs, offices, medical clinics, personal services, veterinary clinics, restaurants, banks, and education, recreation, entertainment and instruction. The bylaw's definition leaves out highway commercial uses, among others. They follow Section 1096.3. (section 1096.1 4) and 102)
- Group child care: licensed care for more than 8 children under 12, such as a nursery school or preschool (group children's day care). It follows Section 1096.3. (section 1096.1 5) and 102)
- Places where people gather for religious, cultural or educational purposes (assembly uses). The bylaw's definition allows one house unit with an assembly use and no other housing. They follow Section 1096.3. (section 1096.1 6) and 102)
Lot size for new lots
- New lots made by subdivision must follow Section 110 of this bylaw and the Subdivision and Development Servicing Bylaw 2019 No. 5382. (section 1096.8)
- New lots made by subdivision must be at least 0.3 ha (0.74 acres). (section 110.1)
How much of the lot buildings may cover
- Buildings and structures may cover at most 40% of the lot. (section 1096.4)
Floor area and density
- The floor space ratio (total floor area of all buildings divided by the lot area) of the land zoned CD-196 may be at most 1.56. (section 1096.2)
- When the floor space ratio is worked out, parking inside the building or underground and indoor age-friendly amenity areas do not count as floor area, and land that a community or neighbourhood plan marks as not able to be built on does not count as lot area. (section 102)
Height
- Buildings and structures may be at most 6 storeys high, plus a rooftop enclosure that gives access to a rooftop amenity area. (section 1096.6)
- Inside the Fort Langley area shown on the map in Section 104.5 3), buildings may be at most 9 m (29 ft 6 in) high and at most 2 storeys, with no room above the second storey. (section 104.5 2))
Distance from the property lines
- The distances buildings must keep from property lines are set in the development permit, a permit from the Township that sets the design of the project. (section 1096.5)
- A heat pump or air conditioner may not be placed on a wall facing a side property line, or inside the required side distance, unless that side faces a side street or lane. It must be at least 1.5 m (4 ft 11 in) from every property line. (section 104.4 12))
Parking
- Parking and loading spaces must follow Section 107 of the bylaw. (section 1096.7)
- Apartments need 1 parking space for each studio and 1.5 spaces for each home with one or more bedrooms, plus 0.5 spaces for each lock-off unit. Another 10% of the required apartment spaces must be for visitors. One space for each main home needs an electric car charging outlet. (section 107.3 a) iii) and note (1))
- For parking, a studio is an apartment of at most 45 m² (484 sq ft) with no walls between the living, dining and kitchen areas and the sleeping area. (section 107.3 a) iii))
- Parking for one-bedroom apartments may be cut by 15% when the lot is within 400 m (1,312 ft) of one of these corners: 86 Avenue and 202 Street (Carvolth Exchange), or 200 Street at 84, 80, 76, 72 or 64 Avenue. Visitor and accessible spaces are not cut. (section 107.1 4))
- An apartment building with 50 to 199 homes needs 1 Class A loading space (at least 7 m (23 ft) long, 2.7 m (8 ft 10 in) wide and 3 m (9 ft 10 in) of clear height). With 200 to 299 homes it also needs 1 Class B space (at least 9.3 m (30 ft 6 in) long, 3.5 m (11 ft 6 in) wide and 4.3 m (14 ft 1 in) of clear height). (section 107.7 1) and 107.8 1))
- Shops, service businesses, personal services (such as hair and nail salons) and liquor stores need 1 parking space for each 35 m² (377 sq ft) of floor area. (section 107.3 c) iv))
- Offices and banks need 1 parking space for each 35 m² (377 sq ft) of floor area. (section 107.3 c) v))
- Restaurants, including brewery or distillery lounges, need 1 parking space for each 35 m² (377 sq ft) of floor area. (section 107.3 c) vi))
- Kindergartens, elementary schools and group child care need 1 parking space for each employee, plus a marked area to drop off and pick up children. Secondary schools and other higher education need 1 space for each employee and 1 space for every 5 students. (section 107.3 b) iii))
- Places of worship, culture and other assembly uses (except schools) need 1 parking space for every 10 seats plus 1 space for each 19 m² (205 sq ft) of floor area used for gatherings. (section 107.3 b) i))
- When a building has more than one use, the parking spaces needed for each use are added together. (section 107.4)
- Lots in the Willowbrook Transit-Oriented Area need no parking spaces for homes, except spaces for people with disabilities. Any spaces built there for homes must have electric car charging outlets. (section 107.1 3))
- When the parking count comes out with a part of 0.5 or more, it is rounded up to the next whole space. (section 107.2 4))
- A commercial building with 500 m² (5,382 sq ft) to 1,999 m² (21,517 sq ft) of floor area needs 1 Class B loading space. Each extra 2,500 m² (26,910 sq ft) of floor area over 1,999 m² (21,517 sq ft), or part of it, needs 1 more Class B space. (section 107.8 1))
- Loading space sizes: Class A is at least 7 m (23 ft) long, 2.7 m (8 ft 10 in) wide and 3 m (9 ft 10 in) high inside. Class B is at least 9.3 m (30 ft 6 in) long, 3.5 m (11 ft 6 in) wide and 4.3 m (14 ft 1 in) high. Class C is at least 23 m (75 ft 6 in) long, 3.5 m (11 ft 6 in) wide and 4.3 m (14 ft 1 in) high. (section 107.7 1))
- Loading spaces do not count toward the parking spaces the bylaw requires. Garbage and recycling must be stored and collected on the lot, without blocking a street. (section 107.8 2) and 3))
Secondary suites
- Each apartment may have one lock-off unit: a small home of at most 45 m² (484 sq ft) attached to the larger apartment through a connecting door or hallway. It may not be sold or stratified apart from the main apartment. (section 102)
- A lock-off unit must be able to be locked off from the main apartment, have a living space at least 4 m (13 ft 1 in) wide and 4 m (13 ft 1 in) long, a sink, a stove or other cooking heat source, a fridge, and at least 3.7 m² (40 sq ft) of closet space. (section 104.20)
Other rules
- Commercial uses, group child care and assembly uses are allowed only on the ground floor of the building. (section 1096.3)
- Landscaping, screens and fences are set in the development permit. (section 1096.9)
- A development with more than 4 townhouse, apartment or seniors' housing homes needs age-friendly amenity areas (shared indoor or outdoor space for the residents' cultural, social and recreation activities): at least 6 m² (65 sq ft) for each of the first 186 homes and 4 m² (43 sq ft) for each home after that. Each area must be at least 70 m² (753 sq ft), and at most half of the required area may be indoors. The development permit also sets them. (section 1096.10, 111.5 1), 2) a) and 6), and 102)
- A development permit (a permit that sets the design of the project) must go to Council for its review before a building permit is issued. (section 1096.11)
- In a residential comprehensive development zone, all home businesses on a lot may use at most 25 m² (269 sq ft) of floor space in total. Everyone who runs the home business must live in that home, and the business may only be an office run mainly by phone, computer or other communication equipment. (section 104.3 f) v), g) iv) and l))
Source: Township of Langley Zoning Bylaw No. 2500, Section 900 Comprehensive Development Zones. Section numbers are the bylaw's own.
Questions about Lot PID 032-864-931
What is the zoning of Lot PID 032-864-931?
Lot PID 032-864-931 is zoned CD-196 (Comprehensive Development Zone CD-196) in the Township of Langley. An apartment zone at a floor space ratio of up to 1.56, with shops, child care and places of worship or culture allowed on the ground floor and buildings up to 6 storeys.
How many homes can I build at Lot PID 032-864-931?
No fixed number for one lot. The number of homes is set by floor area: the floor space ratio of the land zoned CD-196 may be at most 1.56 (all floor area divided by lot area). The bylaw gives no count for one lot.
Can I add a secondary suite at Lot PID 032-864-931?
Each apartment may have one lock-off unit: a small home of at most 45 m² (484 sq ft) attached to the larger apartment through a connecting door or hallway. It may not be sold or stratified apart from the main apartment. A lock-off unit must be able to be locked off from the main apartment, have a living space at least 4 m (13 ft 1 in) wide and 4 m (13 ft 1 in) long, a sink, a stove or other cooking heat source, a fridge, and at least 3.7 m² (40 sq ft) of closet space.
How tall can a house be at Lot PID 032-864-931?
Buildings and structures may be at most 6 storeys high, plus a rooftop enclosure that gives access to a rooftop amenity area. Inside the Fort Langley area shown on the map in Section 104.5 3), buildings may be at most 9 m (29 ft 6 in) high and at most 2 storeys, with no room above the second storey.
How big is the lot at Lot PID 032-864-931?
The lot outline in the Township of Langley map data measures 3,201 m² (34,457 sq ft). The Township's own record lists .785 acres, a figure it marks as not verified. A survey gives the legal figure.
Is Lot PID 032-864-931 on Township sewer and water?
Township records show no sewer service and no water service on Lot PID 032-864-931. A lot without both cannot use the Township's small-scale multi-unit housing rule.
Look up another Langley address
Lot facts come from Township of Langley open data downloaded October 28, 2026, and the urban containment boundary from Metro Vancouver open data. Zone rules come from the zoning bylaw sections named beside each rule. Lot sizes are measured from the lot outlines in that data; a survey gives the legal figure. Bylaws change, so confirm with the Township of Langley before you buy or build. This page gives general information from public records. Only the Township of Langley can approve a plan or a permit.
Contains information licensed under the Township of Langley's Open Government License. Contains information licensed under Metro Vancouver's Open Government Licence.