Willoughby, Township of Langley

Lot PID 025-959-719: zoning and what you can build

Lot PID 025-959-719 is a 810 m² (8,714 sq ft) lot in Willoughby, Township of Langley. It is zoned CD-42 (Comprehensive development). The bylaw sets the highest density by the Willoughby Community Plan and the Southwest Gordon Estate Neighbourhood Plan, and states no number of homes itself. Sources: Township of Langley Zoning Bylaw No. 2500, Section 900 Comprehensive Development Zones, section 942, and Township of Langley lot records downloaded October 28, 2026.

Homes allowed

No fixed number for one lot

The bylaw sets the highest density by the Willoughby Community Plan and the Southwest Gordon Estate Neighbourhood Plan, and states no number of homes itself.

Zone

CD-42

Comprehensive Development Zone CD-42

Lot size

810 m² (8,714 sq ft)

Measured from the lot outline in the public map data.

Home count: Township of Langley Zoning Bylaw No. 2500, Section 900 Comprehensive Development Zones, section 942.2.

N25 m
Lot outline from the public lot map data, to scale, north up.

What the public records say about this lot

Municipality
Township of Langley
Community plan area
Willoughby
Neighbourhood
Southwest Gordon Estate
Lot size (measured from the lot outline)
810 m² (8,714 sq ft)
Lot size the Township records (not verified)
.203 acres
Parcel ID (PID)
025-959-719
Legal description
LT 2, DL 311, NWD, PL BCP10600
Plan number
BCP10600
Sewer service (Township records)
None recorded
Water service (Township records)
None recorded
Agricultural Land Reserve
Outside the reserve
Heritage
No heritage status recorded
Development permit area
Yes, the Township flags this lot
Urban containment boundary (Metro Vancouver)
Inside

Zone CD-42

What zone CD-42 allows

A townhouse zone in the Southwest Gordon Estate area of Willoughby, where density follows the Willoughby Community Plan. Group child care is also allowed.

  • Townhouses (section 942.1 4))
  • A secondary suite (a second home inside the house) (section 102)

What the zone allows

  • Buildings and uses that serve a main use on the same lot (accessory buildings and uses). (section 942.1 1))
  • Home businesses, following Section 104.3. (section 942.1 2))
  • Group child care: licensed care for more than 8 children under 12, such as a nursery school or preschool (group children's day care). (section 942.1 3) and 102)
  • Townhouses: at least 3 homes side by side, joined by shared walls. In a comprehensive development that needs a development permit, a block may have 2 homes and may be combined with houses. (section 942.1 4) and 102)

Lot size for new lots

  • New lots made by subdivision must follow Section 110 of this bylaw and the Subdivision and Development Servicing Bylaw 2019 No. 5382. (section 942.8)
  • New lots made by subdivision must be at least 1,672 m² (17,997 sq ft). (section 110.1)

How much of the lot buildings may cover

  • Buildings and structures may cover at most 40% of the lot. (section 942.4)

Floor area and density

  • The highest density follows the Willoughby Community Plan and the Southwest Gordon Estate Neighbourhood Plan. (section 942.2)

Height

  • Building height is set in the development permit, a permit from the Township that sets the design of the project. (section 942.6)
  • Inside the Fort Langley area shown on the map in Section 104.5 3), buildings may be at most 9 m (29 ft 6 in) high and at most 2 storeys, with no room above the second storey. (section 104.5 2))

Distance from the property lines

  • The distances buildings must keep from property lines are set in the development permit, a permit from the Township that sets the design of the project. (section 942.5)
  • A heat pump or air conditioner may not be placed on a wall facing a side property line, or inside the required side distance, unless that side faces a side street or lane. It must be at least 1.5 m (4 ft 11 in) from every property line. (section 104.4 12))

Parking

  • Parking and loading spaces must follow Section 107 of the bylaw. (section 942.7)
  • Townhouses need 2 parking spaces for each main home, 1 space for each secondary suite, and 1 visitor space for every 5 homes. One space for each main home needs an electric car charging outlet. (section 107.3 a) ii) and note (1))
  • Where spaces are in tandem (one car parked behind another), the rate is 2.3 spaces per home, and at most 40% of the homes in a townhouse development may have tandem spaces. (section 107.3 a) ii))
  • Kindergartens, elementary schools and group child care need 1 parking space for each employee, plus a marked area to drop off and pick up children. Secondary schools and other higher education need 1 space for each employee and 1 space for every 5 students. (section 107.3 b) iii))
  • In a residential comprehensive development zone, up to 20% of the required visitor spaces may be small car spaces, if each one is set at a right angle to the aisle, is at least 2.44 m (8 ft) by 4.88 m (16 ft), and has a sign saying it is for small cars only. (section 107.5 7))
  • Lots in the Willowbrook Transit-Oriented Area need no parking spaces for homes, except spaces for people with disabilities. Any spaces built there for homes must have electric car charging outlets. (section 107.1 3))
  • When the parking count comes out with a part of 0.5 or more, it is rounded up to the next whole space. (section 107.2 4))

Secondary suites

  • Each townhouse home may include one secondary suite, a second home inside the unit of at most 120 m² (1,292 sq ft). (section 102)
  • A home business may not be run inside a secondary suite. (section 104.3 a))

Other rules

  • Amenity areas (landscaped open space the residents can use) must be provided as the development permit sets out. (section 942.3 1) and 102)
  • In multi-family developments that are not adult-oriented, a children's play area with play equipment must also be provided as the development permit sets out. (section 942.3 2))
  • Landscaping, screens and fences are set in the development permit. (section 942.9)
  • A development permit (a permit that sets the design of the project) must go to Council for its review before a building permit is issued. (section 942.10)
  • In a residential comprehensive development zone, all home businesses on a lot may use at most 25 m² (269 sq ft) of floor space in total. Everyone who runs the home business must live in that home, and the business may only be an office run mainly by phone, computer or other communication equipment. (section 104.3 f) v), g) iv) and l))

Source: Township of Langley Zoning Bylaw No. 2500, Section 900 Comprehensive Development Zones. Section numbers are the bylaw's own.

Every lot in zone CD-42

Questions about Lot PID 025-959-719

What is the zoning of Lot PID 025-959-719?

Lot PID 025-959-719 is zoned CD-42 (Comprehensive Development Zone CD-42) in the Township of Langley. A townhouse zone in the Southwest Gordon Estate area of Willoughby, where density follows the Willoughby Community Plan. Group child care is also allowed.

How many homes can I build at Lot PID 025-959-719?

No fixed number for one lot. The bylaw sets the highest density by the Willoughby Community Plan and the Southwest Gordon Estate Neighbourhood Plan, and states no number of homes itself.

Can I add a secondary suite at Lot PID 025-959-719?

Each townhouse home may include one secondary suite, a second home inside the unit of at most 120 m² (1,292 sq ft). A home business may not be run inside a secondary suite.

How tall can a house be at Lot PID 025-959-719?

Building height is set in the development permit, a permit from the Township that sets the design of the project. Inside the Fort Langley area shown on the map in Section 104.5 3), buildings may be at most 9 m (29 ft 6 in) high and at most 2 storeys, with no room above the second storey.

How big is the lot at Lot PID 025-959-719?

The lot outline in the Township of Langley map data measures 810 m² (8,714 sq ft). The Township's own record lists .203 acres, a figure it marks as not verified. A survey gives the legal figure.

Is Lot PID 025-959-719 in the Agricultural Land Reserve?

No. Township of Langley records place Lot PID 025-959-719 outside the Agricultural Land Reserve.

Is Lot PID 025-959-719 on Township sewer and water?

Township records show no sewer service and no water service on Lot PID 025-959-719. A lot without both cannot use the Township's small-scale multi-unit housing rule.

Ask about this lot

Planning to build or renovate at Lot PID 025-959-719?

Tell us what you have in mind. A Venture Pacific builder will check this lot and reply by email. There is no cost.

Look up another Langley address

Lot facts come from Township of Langley open data downloaded October 28, 2026, and the urban containment boundary from Metro Vancouver open data. Zone rules come from the zoning bylaw sections named beside each rule. Lot sizes are measured from the lot outlines in that data; a survey gives the legal figure. Bylaws change, so confirm with the Township of Langley before you buy or build. This page gives general information from public records. Only the Township of Langley can approve a plan or a permit.

Contains information licensed under the Township of Langley's Open Government License. Contains information licensed under Metro Vancouver's Open Government Licence.