Willoughby, Township of Langley
8430 203A StZoning and what you can build
Google Street View nearest the lot. Drag to look around.
What the zoning allows
A strata property
The land is shared by the owners of its 85 units.
Buildings may cover48%
What you can build
- 3 storeys
- Height limit
- 48%
- Largest share of the lot that buildings may cover
- Allowed
- Secondary suite
- Not listed
- Coach house or backyard home
Your lot
- CD-128
- Comprehensive Development Zone CD-128
- Carvolth
- Willoughby plan area
- Not in the ALR
- Agricultural Land Reserve
- 85 units
- Strata property
These figures come from Township of Langley Zoning Bylaw No. 2500, Section 900 Comprehensive Development Zones, section 1028.4 and 1028.6. Where the bylaw sets other figures for some lots or buildings, they are in the full rules further down.
8430 203A St is a strata property in Willoughby, Township of Langley, with 85 units on shared land. It is zoned CD-128 (Comprehensive development). Sources: Township of Langley Zoning Bylaw No. 2500, Section 900 Comprehensive Development Zones, section 1028, and Township of Langley lot records downloaded October 28, 2026.
On the map
8430 203A St from above and from the street
Built by Venture Pacific
Homes and buildings we have built
All projectsZone CD-128
Every rule of zone CD-128
A townhouse zone for at most 183 townhouses, at a floor space ratio of 0.9 to 1.2, with buildings up to 3 storeys.
What the zone allows3 rules
- Buildings and uses that serve a main use on the same lot (accessory buildings and uses). (section 1028.1 1))
- Home businesses, following Section 104.3. (section 1028.1 2))
- Townhouses: at least 3 homes side by side, joined by shared walls. In a comprehensive development that needs a development permit, a block may have 2 homes and may be combined with houses. They follow Section 1028.2. (section 1028.1 3) and 102)
Lot size for new lots2 rules
- New lots made by subdivision must follow Section 110 of this bylaw and the Subdivision and Development Servicing Bylaw 2019 No. 5382. (section 1028.8)
- New lots made by subdivision must be at least 6,800 m² (73,195 sq ft). (section 110.1)
How much of the lot buildings may cover1 rule
- Buildings and structures may cover at most 48% of the lot. (section 1028.4)
Floor area and density1 rule
- The floor space ratio (total floor area divided by lot area) must be at least 0.9 and at most 1.2, as the Carvolth Neighbourhood Plan sets out. (section 1028.2)
Height3 rules
- Main buildings may be at most 3 storeys high and must follow the development permit. (section 1028.6)
- Accessory buildings may be at most 3.75 m (12 ft 4 in) high and 1 storey, whichever is lower. (section 1028.6)
- Inside the Fort Langley area shown on the map in Section 104.5 3), buildings may be at most 9 m (29 ft 6 in) high and at most 2 storeys, with no room above the second storey. (section 104.5 2))
Distance from the property lines2 rules
- The distances buildings must keep from property lines are set in the development permit, a permit from the Township that sets the design of the project. (section 1028.5)
- A heat pump or air conditioner may not be placed on a wall facing a side property line, or inside the required side distance, unless that side faces a side street or lane. It must be at least 1.5 m (4 ft 11 in) from every property line. (section 104.4 12))
Parking6 rules
- Parking and loading spaces must follow Section 107 of the bylaw. (section 1028.7)
- Townhouses need 2 parking spaces for each main home, 1 space for each secondary suite, and 1 visitor space for every 5 homes. One space for each main home needs an electric car charging outlet. (section 107.3 a) ii) and note (1))
- Where spaces are in tandem (one car parked behind another), the rate is 2.3 spaces per home, and at most 40% of the homes in a townhouse development may have tandem spaces. (section 107.3 a) ii))
- In a residential comprehensive development zone, up to 20% of the required visitor spaces may be small car spaces, if each one is set at a right angle to the aisle, is at least 2.44 m (8 ft) by 4.88 m (16 ft), and has a sign saying it is for small cars only. (section 107.5 7))
- Lots in the Willowbrook Transit-Oriented Area need no parking spaces for homes, except spaces for people with disabilities. Any spaces built there for homes must have electric car charging outlets. (section 107.1 3))
- When the parking count comes out with a part of 0.5 or more, it is rounded up to the next whole space. (section 107.2 4))
Secondary suites2 rules
- Each townhouse home may include one secondary suite, a second home inside the unit of at most 120 m² (1,292 sq ft). (section 102)
- A home business may not be run inside a secondary suite. (section 104.3 a))
Other rules4 rules
- Landscaping, screens and fences must follow Section 111 of the bylaw and the development permit. (section 1028.9)
- A development with more than 4 townhouse, apartment or seniors' housing homes needs age-friendly amenity areas (shared indoor or outdoor space for the residents' cultural, social and recreation activities): at least 6 m² (65 sq ft) for each of the first 186 homes and 4 m² (43 sq ft) for each home after that. Each area must be at least 70 m² (753 sq ft), and at most half of the required area may be indoors. The development permit also sets them. (section 1028.10, 111.5 1), 2) a) and 6), and 102)
- Council must issue a development permit (a permit that sets the design of the project) before a building permit is issued. (section 1028.11)
- In a residential comprehensive development zone, all home businesses on a lot may use at most 25 m² (269 sq ft) of floor space in total. Everyone who runs the home business must live in that home, and the business may only be an office run mainly by phone, computer or other communication equipment. (section 104.3 f) v), g) iv) and l))
Source: Township of Langley Zoning Bylaw No. 2500, Section 900 Comprehensive Development Zones. Section numbers are the bylaw's own.
Questions about 8430 203A St
What is the zoning of 8430 203A St?
8430 203A St is zoned CD-128 (Comprehensive Development Zone CD-128) in the Township of Langley. A townhouse zone for at most 183 townhouses, at a floor space ratio of 0.9 to 1.2, with buildings up to 3 storeys.
Can I add a secondary suite at 8430 203A St?
Each townhouse home may include one secondary suite, a second home inside the unit of at most 120 m² (1,292 sq ft). A home business may not be run inside a secondary suite.
How tall can a house be at 8430 203A St?
Main buildings may be at most 3 storeys high and must follow the development permit. Accessory buildings may be at most 3.75 m (12 ft 4 in) high and 1 storey, whichever is lower.
Is 8430 203A St in the Agricultural Land Reserve?
No. Township of Langley records place 8430 203A St outside the Agricultural Land Reserve.
Other lots on 203A St
Look up another Langley address
Lot facts come from Township of Langley open data downloaded October 28, 2026, and the urban containment boundary from Metro Vancouver open data. Zone rules come from the zoning bylaw sections named beside each rule. Lot sizes are measured from the lot outlines in that data; a survey gives the legal figure. Bylaws change, so confirm with the Township of Langley before you buy or build. This page gives general information from public records. Only the Township of Langley can approve a plan or a permit.
Contains information licensed under the Township of Langley's Open Government License. Contains information licensed under Metro Vancouver's Open Government Licence.






