Willoughby, Township of Langley
7059 210 St: zoning and what you can build
7059 210 St is a strata property in Willoughby, Township of Langley, with 119 units on shared land. It is zoned CD-101 (Comprehensive development). Sources: Township of Langley Zoning Bylaw No. 2500, Section 900 Comprehensive Development Zones, section 1001, and Township of Langley lot records downloaded October 28, 2026.
Homes allowed
This is a strata property: the land is shared by the owners of its 119 units, so a count of new homes does not apply to one unit.
Zone
CD-101
Comprehensive Development Zone CD-101
Lot size
Shared strata land
What the public records say about this lot
- Municipality
- Township of Langley
- Community plan area
- Willoughby
- Neighbourhood
- Northeast Gordon Estate
- Strata units
- 119
- Plan number
- EPS3011
- Other addresses on this lot
- 7157 210 St
- Heritage
- No heritage status recorded
- Development permit area
- Yes, the Township flags this lot
- Urban containment boundary (Metro Vancouver)
- Inside
Zone CD-101
What zone CD-101 allows
A townhouse zone for up to 119 townhouses, 14 of them built to the Township's adaptable housing policy. Buildings may be up to 3 storeys.
- Townhouses (section 1001.2)
- A secondary suite (a second home inside the house) (section 102)
What the zone allows
- Buildings and uses that serve a main use on the same lot (accessory buildings and uses). (section 1001.1 1))
- Home businesses, following Section 104.3. (section 1001.1 2))
- Townhouses: at least 3 homes side by side, joined by shared walls. In a comprehensive development that needs a development permit, a block may have 2 homes and may be combined with houses. They follow Section 1001.2. (section 1001.1 3) and 102)
Lot size for new lots
- New lots made by subdivision must follow Section 110 of this bylaw and the Subdivision and Development Servicing Bylaw 2019 No. 5382. (section 1001.7)
- New lots made by subdivision must be at least 1.2 ha (2.97 acres). (section 110.1)
How much of the lot buildings may cover
- Buildings and structures may cover at most 35% of the lot. (section 1001.3)
Height
- Buildings and structures may be at most 3 storeys high. (section 1001.5)
- Inside the Fort Langley area shown on the map in Section 104.5 3), buildings may be at most 9 m (29 ft 6 in) high and at most 2 storeys, with no room above the second storey. (section 104.5 2))
Distance from the property lines
- The distances buildings must keep from property lines are set in the development permit, a permit from the Township that sets the design of the project. (section 1001.4)
- A heat pump or air conditioner may not be placed on a wall facing a side property line, or inside the required side distance, unless that side faces a side street or lane. It must be at least 1.5 m (4 ft 11 in) from every property line. (section 104.4 12))
Parking
- Parking and loading spaces must follow Section 107 of the bylaw and the development permit. (section 1001.6)
- Townhouses need 2 parking spaces for each main home, 1 space for each secondary suite, and 1 visitor space for every 5 homes. One space for each main home needs an electric car charging outlet. (section 107.3 a) ii) and note (1))
- Where spaces are in tandem (one car parked behind another), the rate is 2.3 spaces per home, and at most 40% of the homes in a townhouse development may have tandem spaces. (section 107.3 a) ii))
- In a residential comprehensive development zone, up to 20% of the required visitor spaces may be small car spaces, if each one is set at a right angle to the aisle, is at least 2.44 m (8 ft) by 4.88 m (16 ft), and has a sign saying it is for small cars only. (section 107.5 7))
- Lots in the Willowbrook Transit-Oriented Area need no parking spaces for homes, except spaces for people with disabilities. Any spaces built there for homes must have electric car charging outlets. (section 107.1 3))
- When the parking count comes out with a part of 0.5 or more, it is rounded up to the next whole space. (section 107.2 4))
Secondary suites
- Each townhouse home may include one secondary suite, a second home inside the unit of at most 120 m² (1,292 sq ft). (section 102)
- A home business may not be run inside a secondary suite. (section 104.3 a))
Other rules
- 14 of the townhouses must meet the Basic Adaptable Housing Requirements Policy 07-617 (homes designed so they can be changed for people with limited mobility). (section 1001.2)
- Landscaping, screens and fences are set in the development permit. (section 1001.8)
- The development must have 2,062 m² (22,195 sq ft) of age-friendly amenity areas (shared indoor or outdoor space for the residents' cultural, social and recreation activities), following Section 111.5 and the development permit. (section 1001.9, 111.5 and 102)
- A development permit (a permit that sets the design of the project) must go to Council for its review before a building permit is issued. (section 1001.10)
- In a residential comprehensive development zone, all home businesses on a lot may use at most 25 m² (269 sq ft) of floor space in total. Everyone who runs the home business must live in that home, and the business may only be an office run mainly by phone, computer or other communication equipment. (section 104.3 f) v), g) iv) and l))
Source: Township of Langley Zoning Bylaw No. 2500, Section 900 Comprehensive Development Zones. Section numbers are the bylaw's own.
Questions about 7059 210 St
What is the zoning of 7059 210 St?
7059 210 St is zoned CD-101 (Comprehensive Development Zone CD-101) in the Township of Langley. A townhouse zone for up to 119 townhouses, 14 of them built to the Township's adaptable housing policy. Buildings may be up to 3 storeys.
Can I add a secondary suite at 7059 210 St?
Each townhouse home may include one secondary suite, a second home inside the unit of at most 120 m² (1,292 sq ft). A home business may not be run inside a secondary suite.
How tall can a house be at 7059 210 St?
Buildings and structures may be at most 3 storeys high. Inside the Fort Langley area shown on the map in Section 104.5 3), buildings may be at most 9 m (29 ft 6 in) high and at most 2 storeys, with no room above the second storey.
Other lots on 210 St
- 4758 210 St SR-1
- 6889 210 St R-CL(B)
- 6892 210 St RU-3
- 6933 210 St SR-2
- 6949 210 St SR-2
- 6950 210 St RU-3
- 6955 210 St SR-2
- 6987 210 St SR-2
- 7138 210 St CD-90
- 7215 210 St SR-2
- 7225 210 St SR-2
- 7240 210 St SR-2
- 7245 210 St SR-2
- 7258 210 St SR-2
- 7627 210 St R-1A
- 7633 210 St R-1A
Look up another Langley address
Lot facts come from Township of Langley open data downloaded October 28, 2026, and the urban containment boundary from Metro Vancouver open data. Zone rules come from the zoning bylaw sections named beside each rule. Lot sizes are measured from the lot outlines in that data; a survey gives the legal figure. Bylaws change, so confirm with the Township of Langley before you buy or build. This page gives general information from public records. Only the Township of Langley can approve a plan or a permit.
Contains information licensed under the Township of Langley's Open Government License. Contains information licensed under Metro Vancouver's Open Government Licence.