Township of Langley
6897 Glover Rd: zoning and what you can build
6897 Glover Rd is a 19,399 m² (208,806 sq ft), 4.79 acres lot in Township of Langley. It is zoned CD-167 (Comprehensive development). The zoning allows up to 1 homes on the lot. Sources: Township of Langley Zoning Bylaw No. 2500, Section 900 Comprehensive Development Zones, section 1067, and Township of Langley lot records downloaded October 28, 2026.
Homes allowed
Up to 1 home
Up to 1 home: one home or one mobile home on the lot, only for the owner, manager or caretaker of the business and their immediate family.
Zone
CD-167
Comprehensive Development Zone CD-167
Lot size
19,399 m² (208,806 sq ft), 4.79 acres
Measured from the lot outline in the public map data.
Home count: Township of Langley Zoning Bylaw No. 2500, Section 900 Comprehensive Development Zones, section 1067.4.
What the public records say about this lot
- Municipality
- Township of Langley
- Lot size (measured from the lot outline)
- 19,399 m² (208,806 sq ft), 4.79 acres
- Lot size the Township records (not verified)
- 4.81 acres
- Parcel ID (PID)
- 002-994-020
- Legal description
- LT 2, DL 22, NWD, PL NWP2424
- Plan number
- NWP2424
- Sewer service (Township records)
- None recorded
- Water service (Township records)
- None recorded
- Agricultural Land Reserve
- Outside the reserve
- Heritage
- Township heritage code AP & HBCF
- Development permit area
- Yes, the Township flags this lot
- Urban containment boundary (Metro Vancouver)
- Outside
Zone CD-167
What zone CD-167 allows
An industrial zone for light and general industry, warehouses, trucking terminals, building supply yards, trade contractors, public works yards, bakeries and breweries. One home or mobile home for the owner, manager or caretaker is allowed on each lot.
- A caretaker's home (section 1067.4)
- Mobile homes (section 1067.4)
What the zone allows
- Buildings and uses that serve a main use on the same lot (accessory buildings and uses). (section 1067.1 1))
- Outdoor storage that serves a permitted use, following Section 1067.3. (section 1067.1 2))
- Bakeries. (section 1067.1 3))
- A brewery or distillery licensed under the Liquor Control and Licensing Act. (section 1067.1 4) and 102)
- Building supply stores and lumber yards. (section 1067.1 5))
- Offices that serve a permitted industrial use. (section 1067.1 6))
- Parking of commercial vehicles. (section 1067.1 7))
- Public works yards, and maintenance and storage buildings. (section 1067.1 8))
- Light manufacture, assembly, repair, finishing and packaging of products. (section 1067.1 9))
- Transportation and trucking terminals and yards, including public transit depots. (section 1067.1 10))
- Warehouses, wholesale and storage buildings. Bulk energy storage and bulk storage of industrial chemicals and their by-products are left out. (section 1067.1 11))
- Workshops for building, electrical, heating, air conditioning, plumbing, refrigeration, roofing, septic tank, sign, paving and landscape contractors and similar trades, including sale of garden ornaments, swimming pools and outdoor furniture. (section 1067.1 12))
- General industrial uses: making, putting together, repairing, finishing, packaging and storing products. Heavy industry and similar uses allowed only in the M-3 and M-4 zones, wrecking and salvage yards, and industrial uses that count as reviewable projects under the provincial Environmental Assessment Act are left out. (section 1067.1 13) and 102)
Lot size for new lots
- New lots made by subdivision must follow Section 110 of this bylaw and the Subdivision and Development Servicing Bylaw 2019 No. 5382. (section 1067.9)
- New lots made by subdivision must be at least 1.7 ha (4.2 acres). (section 110.1)
How much of the lot buildings may cover
- Buildings and structures may cover at most 60% of the lot. (section 1067.5)
Height
- Buildings and structures may be at most 12 m (39 ft 4 in) high. (section 1067.7)
- Inside the Fort Langley area shown on the map in Section 104.5 3), buildings may be at most 9 m (29 ft 6 in) high and at most 2 storeys, with no room above the second storey. (section 104.5 2))
Distance from the property lines
- Unless Sections 104.4, 104.15 and 105.1 2) say otherwise, buildings and structures must sit at least 15 m (49 ft 3 in) from every property line. (section 1067.6)
- The distance is 10 m (32 ft 10 in) from a property line next to the rail right-of-way (Plan 22161). (section 1067.6 d))
- No distance is required from an inside rear or inside side property line next to an M zone or a CD zone that permits industrial uses. (section 1067.6 e))
Parking
- Parking and loading spaces must follow Section 107 of the bylaw. (section 1067.8)
- Service, general, heavy and other industrial uses need 1 parking space for each 186 m² (2,002 sq ft) of floor area. (section 107.3 d) i))
- Offices and banks need 1 parking space for each 35 m² (377 sq ft) of floor area. (section 107.3 c) v))
- A home that is part of a commercial or industrial building needs 1.5 parking spaces, and one of them needs a power outlet beside it that can charge an electric car at Level 2 or faster. (section 107.3 a) iv) and note (1))
- When a building has more than one use, the parking spaces needed for each use are added together. (section 107.4)
- When the parking count comes out with a part of 0.5 or more, it is rounded up to the next whole space. (section 107.2 4))
- In a commercial or industrial comprehensive development zone, up to 20% of the required parking spaces may be small car spaces, if each one is set at a right angle to the aisle, is at least 2.44 m (8 ft) by 4.88 m (16 ft), and has a sign saying it is for small cars only. (section 107.5 6))
- An industrial building with 500 m² (5,382 sq ft) to 1,999 m² (21,517 sq ft) of floor area needs 1 Class B loading space. From 2,000 m² (21,528 sq ft) to 5,000 m² (53,820 sq ft) it needs 1 Class B and 1 Class C space. Each extra 5,000 m² (53,820 sq ft) over 5,000 m² (53,820 sq ft), or part of it, needs 1 more Class B and 1 more Class C space. (section 107.8 1))
- Loading space sizes: Class A is at least 7 m (23 ft) long, 2.7 m (8 ft 10 in) wide and 3 m (9 ft 10 in) high inside. Class B is at least 9.3 m (30 ft 6 in) long, 3.5 m (11 ft 6 in) wide and 4.3 m (14 ft 1 in) high. Class C is at least 23 m (75 ft 6 in) long, 3.5 m (11 ft 6 in) wide and 4.3 m (14 ft 1 in) high. (section 107.7 1))
- Loading spaces do not count toward the parking spaces the bylaw requires. Garbage and recycling must be stored and collected on the lot, without blocking a street. (section 107.8 2) and 3))
Other rules
- All business must take place inside a fully enclosed building, except parking, loading and outdoor storage areas that serve a permitted use. (section 1067.2)
- Material in a permitted outdoor storage area may not be placed inside the distances from property lines set in Section 1067.6. (section 1067.3)
- Landscaping, screens and fences must follow Section 111 of the bylaw. (section 1067.10)
Source: Township of Langley Zoning Bylaw No. 2500, Section 900 Comprehensive Development Zones. Section numbers are the bylaw's own.
Questions about 6897 Glover Rd
What is the zoning of 6897 Glover Rd?
6897 Glover Rd is zoned CD-167 (Comprehensive Development Zone CD-167) in the Township of Langley. An industrial zone for light and general industry, warehouses, trucking terminals, building supply yards, trade contractors, public works yards, bakeries and breweries. One home or mobile home for the owner, manager or caretaker is allowed on each lot.
How many homes can I build at 6897 Glover Rd?
Up to 1 home. Up to 1 home: one home or one mobile home on the lot, only for the owner, manager or caretaker of the business and their immediate family.
How tall can a house be at 6897 Glover Rd?
Buildings and structures may be at most 12 m (39 ft 4 in) high. Inside the Fort Langley area shown on the map in Section 104.5 3), buildings may be at most 9 m (29 ft 6 in) high and at most 2 storeys, with no room above the second storey.
How big is the lot at 6897 Glover Rd?
The lot outline in the Township of Langley map data measures 19,399 m² (208,806 sq ft), 4.79 acres. The Township's own record lists 4.81 acres, a figure it marks as not verified. A survey gives the legal figure.
Is 6897 Glover Rd in the Agricultural Land Reserve?
No. Township of Langley records place 6897 Glover Rd outside the Agricultural Land Reserve.
Is 6897 Glover Rd on Township sewer and water?
Township records show no sewer service and no water service on 6897 Glover Rd. A lot without both cannot use the Township's small-scale multi-unit housing rule.
Other lots on Glover Rd
- 6736 Glover Rd C-3
- 6758 Glover Rd SR-2
- 6780 Glover Rd C-3
- 6788 Glover Rd SR-2
- 6840 Glover Rd C-2B
- 6866 Glover Rd P-1
- 6884 Glover Rd SR-2
- 6892 Glover Rd SR-2
- 6902 Glover Rd SR-2
- 6908 Glover Rd SR-2
- 6918 Glover Rd SR-2
- 6924 Glover Rd SR-2
- 6934 Glover Rd SR-2
- 6960 Glover Rd SR-2
- 6968 Glover Rd SR-2
- 6976 Glover Rd SR-2
Look up another Langley address
Lot facts come from Township of Langley open data downloaded October 28, 2026, and the urban containment boundary from Metro Vancouver open data. Zone rules come from the zoning bylaw sections named beside each rule. Lot sizes are measured from the lot outlines in that data; a survey gives the legal figure. Bylaws change, so confirm with the Township of Langley before you buy or build. This page gives general information from public records. Only the Township of Langley can approve a plan or a permit.